The uniform plumbing code states in section 603 4 8 drain lines.
Floor sinkdoh pipe backflow nyc.
608 4 water service piping containment to protect potable water supplies.
Nyc chapter of the american society of sanitary engineers p o.
A property owner must install an approved backflow prevention device on every water service pipe that has a connection between the drinking water supply and a potential source of contamination such as a business process or equipment that could potentially contaminate the water supply.
Want to know where to buy zurn products.
It is a 6 page new section covering fixture calculations various occupancy types a new table of required fixtures and a new table covering the minimum number of required fixtures.
Box 293 grand central sta ny 10163.
But before we get into the details and benefits of a sewer backwater valve let s explain what backwater is.
Once the owner became aware of a device called a knife edged sewer flood gate valve they contacted joseph l.
Electrical panels boilers chillers storage tanks fire pumps fire sprinkler risers etc.
When it comes to installing a sewer backflow preventer balkan is at the forefront of the nyc plumbing industry in terms of knowledge and expertise.
Box 20111 greeley square sta ny 10001.
Drain lines serving backflow devices or assemblies shall be sized in accordance with the discharge rates of the manufacturer s flow charts of such devices or assemblies.
1829 mm above the floor.
American institute of architects aia aia ny chapter center for architecture 536.
Section pc 403 of the new york city plumbing code is repealed and a new section pc 403 is added to cover minimum plumbing facilities.
Nyc chapter of the american society of plumbing engineers p o.
For some backflow protection installations a drain may be required.
The item in the picture to the right is referred to as a floor sink.
Select from our list of national distributers or search by city rep distributer or wholesale.
A plumbing floor plan plan view or partial floor plan indicating water services name and address of facility water meter layout proposed backflow preventer s booster pump system floor drain s and all nearby objects examples.
Floor sink as a waste receptor.
A licensed plumber or engineer can advise a building owner on whether or not they have cross connection.
2015 international plumbing code amended backflow cross connection control requirements.
Water service piping shall be protected in accordance with sections 603 2 and 603 2 1.