Like smoke detectors co alarms need to be tested regularly and cleaned as indicated in the manufacturer s use and care booklet.
Floor mount fire alarm.
Electromagnetic door holders and releasers keep doors open until they are released by fire alarm systems remote smoke detectors or other switching devices.
If the unit operates off a battery test the detector weekly and replace the battery at least once a year.
The catch plate assembly may be mounted to the door either by through bolting or by using the concealed surface mounting plate.
Also make sure you do not place a co detector directly next to a fuel burning appliance.
Mount smoke alarms high on walls or ceilings remember smoke rises.
The strobe is always located in the center of the coverage area.
In rooms without a fuel burning appliance or an open fire put the co alarm close to the breathing zone.
Electromagnetic floor mounted fire door holders are ideally suited to applications where maximum protection is needed against vandalism or accidental damage.
Designed to be used on self closing swinging doors to automatically isolate an area when activated by fire alarm smoke detection or sprinkler systems.
A plan view of a ceiling mounted fire alarm notification device s coverage area shows that the coverage projects outward along the strobe s mounting surface at an equal distance on all sides creating the square coverage areas listed in nfpa 72.
Install detectors on or as near to the ceiling as possible.
Designed for virtually any remote door release application electromagnetic door holders releases can be be tripped by an alarm or smoke detector or triggered by a remote switch.
Many smoke detectors are designed to mount to a ceiling but some can also be wall mounted when attaching to a ceiling isn t feasible.
It features a rugged cast aluminium housing a holding electromagnet with integral anti residual ejection pin and a manual release switch.
Floor mounted available for single doors or two doors mounted back to back adequate space must be considered for floor mounted holder releases.
Mount it between 3 feet about 1 m and 10 feet about 3 m horizontally from the nearest edge of the potential source.
If you have ceilings that are pitched install the alarm within 3 feet of the peak but not within the apex of the peak four inches down from the peak.
Designed to be housed in either eaton s own 19 floor rack unit 39uecrack or in non eaton 19 rack units the r6000 range enables buildings to house the fire alarm control panel either in server rack or control rooms instead of mounted to the wall.
In the event of a power failure they release the door to a closed position to keep the facility secure.